Marvel nugget ice machine with all lamps lit steady (Er25): too cold
Er25 is a low-temperature stop.
Mon–Sat, 8am–8pm
- Cooling system
- Ice machine compressor and sealed system repair
- Source: Marvel
Book a visit
Three short steps, about a minute.
or call (844) 410-9163
Loading appointment form…
The appointment form couldn’t load. Please try again.
What Er25
actually means.
Er25 is a low-temperature stop. Marvel ties it to a cold room and asks for the machine to run where the air is above 50°F. It shows up most on outdoor models in cool weather.
Marvel ice machine display · also shown as ICE, NO WATER and DRAIN lamps lit
What to do when Er25 shows on the ice machineKind of codeCooling system
The board saw temperatures or pressures that the sealed system should never reach: a discharge line too hot, a suction side that never cools, or a compressor that starts and stops on its overload. A dirty condenser can push a healthy system into this family, so it is the first thing to rule out; a low charge, a leak or a tired compressor is not. On many current machines that system holds R-290, which is flammable, and only a technician opens it.
Usually leads toIce machine compressor and sealed system repair
The compressor, its start parts and the sealed system, including machines on flammable R-290, tested for pressure and leaks and repaired by the maker's procedure.
Shows up asIce Machine Error Code or Flashing Light: What It Is Telling You
An ice machine error code may show as a number on a small display, a pattern of blinking lights on the control board, a colored light on the front, or a machine that stops with one indicator flashing.
MakeMarvel
Marvel ice machine visits in a home start with the drain and the water supply, then move to the clear ice cycle.
SourceMarvel MRNP215 nugget ice machine owner's guide and service manual
Marvel nugget ice machines MRNP215, MONP215 and MANP415, which report through ICE, NO WATER and DRAIN lamps.
Before you book,
in this order.
Each step comes from Marvel's own guidance for Er25 on its ice machines. Follow it to the end: the last card says whether this is a visit.
Check the air temperature around the machine.
If it is below 50°F, turn the machine off until the space warms, then restart it.
If the lamps light steady in a warm room, book a visit to test the evaporator sensor.
Still there?
It usually turns into ice machine compressor and sealed system repair. Book with the code and the model number.
What not to do
Lamps lit steady are not the same as lamps blinking; all three blinking is a warm-evaporator signal. A single steady DRAIN lamp is just the drain valve open.
What you may
notice with it.
The ice machine problems Er25 tends to arrive with. Answer these at the ice machine before anyone is booked.
All problemsWhere Er25 usually leads
Ice machine compressor and sealed system repair.
Marvel
ice machines.
Marvel ice machine visits in a home start with the drain and the water supply, then move to the clear ice cycle.
Marvel ice machine repairMore Marvel codes
Cooling system on other makes
All 13 codes of this kind
Undercounter ice machine
A self-contained ice machine that makes and stores its own ice under a bar, a service counter or a kitchen island, from commercial units to clear-ice models in large homes.
Nugget ice machine
An ice machine that freezes a thin layer inside a chilled cylinder and pushes it out with an auger as soft, chewable nuggets, for clinics, offices, hotels and large homes.
In Marvel's own words
When the evaporator outlet temperature drops below the set temperature for 2 minutes while the ice maker is running (Er25)
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Marvel nugget ice machines MRNP215, MONP215 and MANP415, which report through ICE, NO WATER and DRAIN lamps.
Marvel Er25 ice machine repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about Er25.
Can I clear Er25 myself?
Why does my outdoor Marvel nugget machine stop in the fall?
Does Er25 damage a Marvel nugget machine?
Can I run my Marvel nugget machine in an unheated garage?
Back to your everyday
Still showing Er25?
A booking with a code goes further when it carries the light or code copied as it appeared, the model and serial off the data plate, and a word on whether cubes still fall into the bin. With those three in hand, our office can match the probable part to your machine the same afternoon.