U-Line nugget ice machine with all three lamps blinking (Er01)

Once ice making starts, the evaporator should drop well below freezing.

(844) 410-9163

Mon–Sat, 8am–8pm

  • Cooling system
  • Ice machine compressor and sealed system repair
  • Source: U-Line

Book a visit

Three short steps, about a minute.

or call (844) 410-9163

What Er01
actually means.

Once ice making starts, the evaporator should drop well below freezing. If it is still at 32°F or above after 30 minutes, the control blinks ICE, NO WATER and DRAIN together and records Er01. U-Line's service steps include a refrigerant leak check and a sensor check, so this is a sealed-system question.

U-Line ice machine display · also shown as ICE, NO WATER and DRAIN lamps blinking

What to do when Er01 shows on the ice machine

Before you book,
in this order.

Each step comes from U-Line's own guidance for Er01 on its ice machines. Follow it to the end: the last card says whether this is a visit.

01

Turn the machine off and check that the condenser grille at the front is not blocked.

02

Make sure the room is within the range the guide allows for the model.

03

Book a visit; U-Line asks for power to be restored only after the cooling problem is solved, and a leak check on R-290 is a technician's job.

Still there?

It usually turns into ice machine compressor and sealed system repair. Book with the code and the model number.

What not to do

Er01 is the 30-minute check; Er03, with only the ICE lamp blinking, is a similar warm-evaporator check made at 10 minutes. All three lamps lit steady, not blinking, is Er25, the opposite problem of an evaporator that got too cold.

Where Er01 usually leads

Ice machine compressor and sealed system repair.

Compressor start parts, leak repair, evaporator or compressor replacement · highest.

In U-Line's own words

passed during the ice making (Er01).
U-Line URNP115 15-inch nugget ice machine user guide U-Line URNP115 15-inch nugget ice machine user guide U-Line URNP115 15-inch nugget ice machine user guide

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. U-Line 1 Class RNP115 and Outdoor ONP115 nugget ice machines, which report through the ICE, NO WATER and DRAIN lamps beside the light button.

U-Line Er01 ice machine repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A family filling glasses with nugget ice from an ice machine in a large home kitchen.
For the heart of your home.

Questions
about Er01.

Can I clear Er01 myself?
Turn the machine off and check that the condenser grille at the front is not blocked. If it comes back, it needs a visit.
Does Er01 on my U-Line nugget machine mean a leak?
It can. A leak check is on U-Line's list for this pattern, along with the sensor and its mounting.
Can I clear Er01 by unplugging the U-Line?
Power can be cut and restored, but U-Line asks for the cooling problem to be fixed first, so the pattern will return if nothing changed.
What if I smell gas near a U-Line with all lamps blinking?
Leave switches and flames alone, open windows, step out and book a visit; call 911 if the smell is strong. These machines run on a flammable refrigerant.

Back to your everyday

Still showing Er01?

A booking with a code goes further when it carries the light or code copied as it appeared, the model and serial off the data plate, and a word on whether cubes still fall into the bin. With those three in hand, our office can match the probable part to your machine the same afternoon.

(844) 410-9163 Schedule a repair