Manitowoc E11: the cooling system did not respond at start-up
After the compressor starts, an Indigo board expects the discharge line to warm and the evaporator to cool by at least ten degrees before the freeze is two minutes old.
Mon–Sat, 8am–8pm
- Cooling system
- Ice machine compressor and sealed system repair
- Source: Manitowoc
Book a visit
Three short steps, about a minute.
or call (844) 410-9163
Loading appointment form…
The appointment form couldn’t load. Please try again.
What E11
actually means.
After the compressor starts, an Indigo board expects the discharge line to warm and the evaporator to cool by at least ten degrees before the freeze is two minutes old. If neither moves enough, it logs E11. A compressor that is not really pumping, a contactor that did not pull in, a sealed system short of charge, or a valve stuck open are the kinds of problems behind it.
Manitowoc ice machine display
What to do when E11 shows on the ice machineKind of codeCooling system
The board saw temperatures or pressures that the sealed system should never reach: a discharge line too hot, a suction side that never cools, or a compressor that starts and stops on its overload. A dirty condenser can push a healthy system into this family, so it is the first thing to rule out; a low charge, a leak or a tired compressor is not. On many current machines that system holds R-290, which is flammable, and only a technician opens it.
Usually leads toIce machine compressor and sealed system repair
The compressor, its start parts and the sealed system, including machines on flammable R-290, tested for pressure and leaks and repaired by the maker's procedure.
Shows up asIce Machine Error Code or Flashing Light: What It Is Telling You
An ice machine error code may show as a number on a small display, a pattern of blinking lights on the control board, a colored light on the front, or a machine that stops with one indicator flashing.
MakeManitowoc
With a Manitowoc ice machine, the technician notes what the controls report and checks the bin control before opening the cycle for testing.
SourceManitowoc Indigo Series air, water and remote condenser ice machines technician's handbook (Part Number 000014794)
Air- and water-cooled Indigo heads only; on G-board firmware 4.017 and later it is Event Log only, with no alert.
Before you book,
in this order.
Each step comes from Manitowoc's own guidance for E11 on its ice machines. Follow it to the end: the last card says whether this is a visit.
Check that the head is on its correct circuit and that the breaker has not tripped.
Restart the head once with the On/Off button and listen for the compressor starting.
If E11 repeats, leave the head off and book a visit; the next checks are on the sealed system and its electrical parts.
Still there?
It usually turns into ice machine compressor and sealed system repair. Book with the code and the model number.
What not to do
E11 is not a sensor reading out of limits; those are E21 to E24. A water problem that keeps the plate from freezing is logged as E20 instead.
What you may
notice with it.
The ice machine problems E11 tends to arrive with. Answer these at the ice machine before anyone is booked.
All problemsWhere E11 usually leads
Ice machine compressor and sealed system repair.
Manitowoc
ice machines.
With a Manitowoc ice machine, the technician notes what the controls report and checks the bin control before opening the cycle for testing.
Manitowoc ice machine repair
Modular ice machine
An ice-making head set on top of a separate storage bin or drink dispenser, cooled by air, water or a condenser on the roof, turning out hundreds of pounds of cubes a day.
Undercounter ice machine
A self-contained ice machine that makes and stores its own ice under a bar, a service counter or a kitchen island, from commercial units to clear-ice models in large homes.
Nugget ice machine
An ice machine that freezes a thin layer inside a chilled cylinder and pushes it out with an auger as soft, chewable nuggets, for clinics, offices, hotels and large homes.
In Manitowoc's own words
The compressor discharge temperature did not increase by at least 10 F
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Air- and water-cooled Indigo heads only; on G-board firmware 4.017 and later it is Event Log only, with no alert.
Manitowoc E11 ice machine repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about E11.
Can I clear E11 myself?
My Manitowoc logged E11 and the water runs but nothing freezes. What now?
Could E11 on a Manitowoc be a refrigerant leak?
Does E11 happen on every Manitowoc model?
Back to your everyday
Still showing E11?
A booking with a code goes further when it carries the light or code copied as it appeared, the model and serial off the data plate, and a word on whether cubes still fall into the bin. With those three in hand, our office can match the probable part to your machine the same afternoon.