A Manitowoc head stops when falling ice holds the water curtain or ice damper open, and restarts when it swings shut.

(844) 410-9163

Mon–Sat, 8am–8pm

  • Sensors and bin control
  • Ice machine bin control repair
  • Source: Manitowoc

Book a visit

Three short steps, about a minute.

or call (844) 410-9163

What E12
actually means.

A Manitowoc head stops when falling ice holds the water curtain or ice damper open, and restarts when it swings shut. If the switch reads open for 24 hours on G-board heads (12 hours on E-board heads), the board assumes the curtain is off, stuck or its magnet or switch has failed, and logs E12.

Manitowoc ice machine display

What to do when E12 shows on the ice machine

Before you book,
in this order.

Each step comes from Manitowoc's own guidance for E12 on its ice machines. Follow it to the end: the last card says whether this is a visit.

01

Check whether the bin really is full up to the curtain; if so, E12 may simply reflect low ice use.

02

Lift out any ice holding the curtain or damper open and make sure the curtain hangs in place and swings freely.

03

If the curtain is free and the head still will not start, book a visit to test the curtain switch.

Still there?

It usually turns into ice machine bin control repair. Book with the code and the model number.

What not to do

E12 does not mean the ice falls slowly; that is E02. A full bin by itself is normal and does not become E12 until the time limit passes.

Where E12 usually leads

Ice machine bin control repair.

Bin thermostat, paddle, curtain switch or ice-level sensor · low.

In Manitowoc's own words

The ice machine is set to ice making and remains in bin full condition for more than 24 hours.
Manitowoc Indigo Series air, water and remote condenser ice machines technician's handbook (Part Number 000014794) Manitowoc Indigo Series air, water and remote condenser ice machines technician's handbook (Part Number 000014794)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. E-board heads log it after 12 hours and G-board heads after 24 hours (firmware 4.017 and later).

Manitowoc E12 ice machine repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A family filling glasses with nugget ice from an ice machine in a large home kitchen.
For the heart of your home.

Questions
about E12.

Can I clear E12 myself?
Check whether the bin really is full up to the curtain; if so, E12 may simply reflect low ice use. If it comes back, it needs a visit.
Why is my Manitowoc logging E12 after a slow weekend?
If nobody took ice for a day, the curtain stayed open against a full bin the whole time. That fits the definition without anything being broken; the head restarts once ice is used.
Can a missing water curtain cause E12 on a Manitowoc?
Yes. A curtain left out after cleaning looks like a permanently open switch. Put it back and make sure it swings freely.
Does E12 mean the curtain switch has failed?
Sometimes. If the curtain is in place, hangs closed and the bin is not full, the switch or its magnet needs testing.

Back to your everyday

Still showing E12?

A booking with a code goes further when it carries the light or code copied as it appeared, the model and serial off the data plate, and a word on whether cubes still fall into the bin. With those three in hand, our office can match the probable part to your machine the same afternoon.