Manitowoc E19: ice thickness probe signal lost

The Indigo ice thickness probe tells the board when the sheet of ice is thick enough to harvest.

(844) 410-9163

Mon–Sat, 8am–8pm

  • Sensors and bin control
  • Ice machine bin control repair
  • Source: Manitowoc

Book a visit

Three short steps, about a minute.

or call (844) 410-9163

What E19
actually means.

The Indigo ice thickness probe tells the board when the sheet of ice is thick enough to harvest. If its signal drops outside the expected band, because the probe is unplugged, scaled over or damaged, the board logs E19. With five good cycles of history it keeps the head running in safe mode for up to 72 hours.

Manitowoc ice machine display

What to do when E19 shows on the ice machine

Before you book,
in this order.

Each step comes from Manitowoc's own guidance for E19 on its ice machines. Follow it to the end: the last card says whether this is a visit.

01

Check the display for a safe mode alert; the head may still be making ice on timed cycles.

02

Plan a de-scale and sanitize, since scale on the probe is a common reason it misreads.

03

Book a visit before the 72 hours run out, so the probe can be cleaned, adjusted or replaced.

Still there?

It usually turns into ice machine bin control repair. Book with the code and the model number.

What not to do

E19 is not a water level problem, which the board logs as E20. It also does not mean the freeze is slow; a probe that reads but calls too late produces E01.

Where E19 usually leads

Ice machine bin control repair.

Bin thermostat, paddle, curtain switch or ice-level sensor · low.

In Manitowoc's own words

E19 Ice Thickness Probe Fault
Manitowoc Indigo Series air, water and remote condenser ice machines technician's handbook (Part Number 000014794) Manitowoc Indigo Series air, water and remote condenser ice machines technician's handbook (Part Number 000014794) Manitowoc Indigo NXT ice machines installation, operation and maintenance manual (Part Number 040009662 Rev 02)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Indigo heads; on G-board firmware 4.017 and later it is Event Log only, and the machine relies on safe mode.

Manitowoc E19 ice machine repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A family filling glasses with nugget ice from an ice machine in a large home kitchen.
For the heart of your home.

Questions
about E19.

Can I clear E19 myself?
Check the display for a safe mode alert; the head may still be making ice on timed cycles. If it comes back, it needs a visit.
My Manitowoc still makes ice after E19. Is it fixed?
Not yet. Safe mode runs the head on the times it learned from recent cycles, and after 72 hours it goes to standby. Use that window to get the probe looked at.
Can dirty water cause E19 on a Manitowoc?
Scale and slime on the probe change what it senses, and the manual names a dirty probe among the reasons a head will not harvest. Cleaning often helps.
Why are my Manitowoc cubes thin after an E19 entry?
Without the probe, cycle length is estimated, so the cubes can come out thinner or thicker than usual until the probe works again.